Reinforcing existing rockfall protection fences! Stronger Method [*with construction examples*]

Rockfall capture performance is more than doubled! Reinforcement and height increase of the fence can be achieved without special processing!

The Stronger Method is a completely new rockfall countermeasure technique that utilizes existing rockfall protection fences without any special processing for reinforcement and achieves an increase in fence height. It allows for a "simple, inexpensive, and short-term" increase in fence height, with rockfall capture performance more than doubled! It is compatible with both newly installed and existing H-beam type rockfall protection fences. *We are currently offering a catalog with case studies of the Stronger Method, which has also been adopted by the Ministry of Land, Infrastructure, Transport and Tourism! Please download for more details. 【Features】 ■ No need for large-scale traffic regulations or detours due to heavy machinery! ■ Reinforcement is done without processing, allowing for quick and economical construction! ■ NETIS Registration No: HR-140004-A *For more details, please contact us or download the catalog to view.

  • Protective fence

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Groundbreaking rockfall prevention method "Stronger Method" *Case study collection giveaway

Easily, cheaply, and quickly raise the height of the existing stone guard! [Check the easy installation in the video]

We are currently offering a catalog featuring case studies of the Stronger Method, which has been adopted by the Ministry of Land, Infrastructure, Transport and Tourism! For more details, please download it. The Stronger Method is a completely new rockfall countermeasure technique that utilizes existing rockfall protection fences without any special processing, allowing for reinforcement and an increase in fence height. It can raise the fence height "easily, inexpensively, and in a short period," and the rockfall capture performance is more than doubled! It is compatible with both new and existing H-beam type rockfall protection fences. Adoption Case (Ministry of Land, Infrastructure, Transport and Tourism) ● Initially planned to "break down the retaining wall → new construction," but wanted to minimize damage to the retaining wall as it had been repaired multiple times.  → No need for any demolition (or core drilling) of the retaining wall concrete. ● As it is a major national road, we wanted to shorten the traffic regulation period.  → Only one day of regulation during material delivery (normally, regulations last about two weeks). ● We wanted to utilize existing stock and reduce costs.  → No processing required for existing structures, resulting in about a 20% cost reduction compared to new construction. *For more details about the case studies, please contact us or download the catalog to view.

  • キャプチャ1.PNG
  • キャプチャ11.PNG
  • Protective fence

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Reinforcement and Height Increase of Rockfall Protection Fences Utilizing Existing Structures

Numerous examples and benefits of the "Stronger Method" are featured with color photographs!

This document is about the simple construction method "Stronger Method" for attaching components to existing rockfall protection fences. It includes numerous examples with photos based on requests such as, "We planned to demolish and rebuild the retaining wall, but we have repaired it multiple times and want to minimize damage to the wall," and "Since this is a major national road, we want to shorten the traffic regulation period." Additionally, the features and benefits of the "Stronger Method" are also introduced. [Contents (excerpt)] ■ What is Stone Guard? ■ Application range of the Stronger Method ■ Features of the Stronger Method ■ Mechanism of the Stronger Method ■ Examples of adoption *For more details, please refer to the PDF document or feel free to contact us.

  • Protective fence

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Examples of Stronger Method Adoption: Fukushima Prefecture

Change the height from 1.5m to 2.5m with a raised type to accommodate your desired fence height.

We would like to introduce an example of the "Stronger Method," which is a reinforcement work for rockfall protection fences utilizing existing structures in Fukushima Prefecture. There were rockfalls that exceeded the fence, and there was a desire to increase the height of the fence. Additionally, it was adopted with consideration for the landscape and to accommodate landscape colors. The height was changed from 1.5m to 2.5m using a raised type to meet the desired fence height. Furthermore, we were able to accommodate landscape colors with hot-dip galvanized coating plus painting. 【Adoption Example】 ■ Location: Fukushima Prefecture ■ Type: Raised type ■ Reasons for Adoption - There were rockfalls that exceeded the fence, and there was a desire to increase the height of the fence. → Addressed with a raised type (H = 1.5m to 2.5m) - There was a desire to accommodate landscape colors with consideration for the landscape. → Possible to accommodate with hot-dip galvanizing plus painting. *For more details, please refer to the PDF materials or feel free to contact us.

  • image_05.jpg
  • image_06.jpg
  • Rockfall prevention agent

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Stronger Method Adoption Example: Yamanashi Prefecture

Change the height from 2m to 3m! This method allows for approximately half the cost and a significant reduction in construction time.

We would like to introduce an example of the "Stronger Method," a rockfall protection fence reinforcement project that utilizes existing structures in Yamanashi Prefecture. There were instances of rockfalls exceeding the fence, and there was a desire to increase the height of the fence. Additionally, although a high-energy protection fence had already been designed, it was costly. There were also bent posts that the client wanted to reuse if possible, which led to the adoption of this method. The height was changed from 2m to 3m using a raising type to meet the desired fence height. Furthermore, this method allows for approximately half the cost and significant shortening of the construction period. Regarding the bent posts, part of the base of the posts was retained and raised to accommodate the situation. 【Adoption Example】 ■ Location: Yamanashi Prefecture ■ Type: Raising Type ■ Reasons for Adoption - There were rockfalls exceeding the fence, and there was a desire to increase the fence height. → Addressed with the raising type (H=2.0→3.0m) - A high-energy protection fence had already been designed, but it was costly. → Approximately half the cost and significant shortening of the construction period. - There were bent posts that the client wanted to reuse. → Raised by retaining part of the base of the posts. *For more details, please refer to the PDF materials or feel free to contact us.

  • image_10.jpg
  • image_11.jpg
  • Rockfall prevention agent

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Hyogo Prefecture Construction Case Study: Reinforcement Method for Existing Rockfall Protection Fences, Usable Without Small Heavy Machinery.

Simple construction! This method allows for an increase in fence height using raised components.

Here is a case study of the "Stronger Method" conducted in Hyogo Prefecture. As a result of the construction, the fence height increased from 2.0m to 3.0m, with a construction length of L = 39.5m. This method restrains the twisting of the posts with upper and lower reinforcement brackets, allowing for buckling prevention at the base of the posts. Additionally, since no small machinery is used, there is no need to cut down surrounding trees. [Case Study] ■ Raised type (Fence height: H = 2.0 → 3.0m, Construction length: L = 39.5m) ■ Hyogo Prefecture (Construction: Fiscal Year 2018) *For more details, please refer to the PDF document or feel free to contact us.

  • Protective fence

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Reinforcement work for existing rockfall protection fence "Reinforced Fence"

Reuse the existing rockfall protection fence as is to improve performance.

The "Reinforced Fence" is a method for strengthening existing rockfall protection fences that lack durability and height. It can increase the height of the protection fence up to a maximum of 6.0 meters and enhance the corresponding rockfall energy up to a maximum of 200 kJ. ■ Reinforcement of existing rockfall protection fences ■ Height increased up to a maximum of 6.0 meters ■ Rockfall energy increased up to a maximum of 200 kJ Ministry of Land, Infrastructure, Transport and Tourism New Technology Information System (NETIS) Registration Number: HR-110028-V *Registration period has ended *For more details, please download the PDF or feel free to contact us.

  • Road construction
  • Railway Construction
  • Other civil engineering works

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Rockfall prevention construction method "Stronger Method" *Construction case examples available

Utilizing existing rockfall protection fences! Achieving both short construction periods and low costs without the need for special equipment. Proven results in railways and other applications.

The "Stronger Method" is a rockfall countermeasure technique that allows for reinforcement and heightening of existing rockfall protection fences without processing or dismantling them. No special equipment or skills are required, and it can be completed in just a few days. It enhances rockfall capture performance with "short construction periods and low costs." It is compatible with H-beam type protection fences and has been widely adopted in railways and highways. Currently, we are offering a collection of case studies for construction near railways. 【Features】 ■ Construction costs are lower compared to new installation of protection fences ■ Can be constructed without special equipment such as heavy machinery ■ Short construction periods allow for brief traffic restrictions ■ Achieved reinforcement of approximately 30 meters of protection fence in 3 days ■ NETIS registered method (Number: HR-140004-A) *Catalogs and case study collections can be viewed via "PDF Download."

  • Renovation and repair methods

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Stronger Method Adoption Example] Replacement of Bent Columns

The construction period is one day! The cost is less than half compared to base plate type or when demolishing and rebuilding.

Our company offers a rockfall protection fence reinforcement method called "Stronger Method," which allows for the reuse of bent posts by utilizing existing structures. First, remove the wire attachment fittings and cut the post at the base (250mm from the top). Then, attach the post connection member (only bolted). Next, install the raised post and reattach the removed wire attachment fittings. Compared to base plate systems or complete demolition and new installation, the cost is less than half, and the construction period can be completed in one day. [Example of Adoption] ■ Location: Yamanashi Prefecture ■ Type: Raised type ■ Work Procedure 1. Remove the wire attachment fittings and cut the post at the base (250mm from the top). 2. Attach the post connection member (only bolted). 3. Install the raised post and reattach the removed wire attachment fittings. *For more details, please refer to the PDF document or feel free to contact us.

  • image_02.jpg
  • image_04.jpg
  • image_03.jpg
  • Rockfall prevention agent

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Shizuoka Prefecture construction case study: Reinforcement method for existing rockfall protection fences - Noise control measures during demolition!

Noise, dust, and high alkaline water treatment measures during demolition are not required. It is a simple construction method.

Here is a case study of the "Stronger Method" implemented in Shizuoka Prefecture. As a result of the construction, the fence height increased from 1.5m to 2.0m, with a construction length of L = 30.0m. This method connects the tops of the posts with steel rods, allowing the load that was previously supported by a single span to be distributed across multiple spans. Additionally, in areas where there are concerns about insufficient fence height, height-raising materials can be used to increase the fence height. [Case Study] ■Height-raising type (Fence height: H = 1.5 → 2.0m, Construction length: L = 30.0m) ■Shizuoka Prefecture (Construction: Fiscal Year 2018) *For more details, please refer to the PDF document or feel free to contact us.

  • Protective fence

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Reinforcement work for existing rockfall protection fence "Reinforced Fence Type L"

Ideal for improving the insufficient height of existing rockfall protection fences and addressing aging issues.

The "Reinforced Fence L Type" is a reinforcement method that addresses the improvement of insufficient fence height and countermeasures for aging existing fences. By reusing the existing retaining wall, the construction period can be shortened compared to conventional measures. Previously, improving insufficient fence height required the removal and reinstallation of the fence or raising the height of the retaining wall with concrete. The Reinforced Fence L Type allows for the installation of new post bases on the retaining wall while keeping the existing posts in place, enabling the erection of new posts. This simple process reduces the overall cost of the project. ■ Compatible with falling rock energy below 61 kJ ■ Reuses existing retaining walls of falling rock protection fences ■ Reduces waste materials and lowers environmental impact ■ Shortens construction period and reduces waste disposal costs ■ Reduces road occupancy time during construction ■ Can be installed with a simple process *For more details, please download the PDF or feel free to contact us.

  • Road construction
  • Railway Construction
  • Other civil engineering works

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Hyogo Construction Case Study: Railway Proximity Work - Reinforcement and Elevation of Existing Protective Fences

A case of railway proximity work where reinforcement and elevation of the existing protective fence were carried out!

Here is a case study of the "Stronger Method" implemented in Hyogo Prefecture. As a result of the construction, the fence height increased from 1.55m to 3.0m, with a construction length of L = 13.0m. This method distributes the load, which was previously supported by a single span in conventional methods, across multiple spans by connecting the tops of the posts with steel rods. Additionally, in areas where there are concerns about insufficient fence height, height-raising materials can be used to increase the fence height. [Case Study] ■ Height-raising reinforcement type (Fence height: H = 1.55 → 3.0m, Construction length: L = 13.0m) ■ Hyogo Prefecture (Construction: FY 2015, Railway proximity work) *For more details, please download the PDF or feel free to contact us.

  • Protective fence

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration